MAK 2000 Plus

Convenient patient positioning


The chin hollow facilitates the positioning of standing or
seated patients for chest examinations.
Minimal space requirements - Easy installation
The MAK 2000 with its small center column can be xed to the
wall as well as installed free standing with the optional
support. The operator controls can be changed from left to the
right during installation


MAK 2000 Plus at a glance

 

  • Eortless 4-way oating tabletop
  • Smooth High/ Low movements
  • Patient lift capacity of 750 lbs (320 kg)
  • Electro-magnetically braked
  • Built-in option for X-Ray generator integration
  • Multiple upgrade options thanks to modular design
  • Contact safety device interrupts travel to avoid collision
  • Safe-click operator function to avoid accidental activation

Specifications

Table and Integrated Tube Stand with Tube and Collimator


• Column Height – 2276mm (89.6”)
• Column Pivot (Optional, for Lateral Exposures) - +/-90 degrees
• Column Travel from Centerline of Table – 880mm (34.6”) to Left,
560mm (22”) to Right, (Standard Version)
880mm (34.6”) to Right,
560mm (22”) to Left, (Right Hand Version)
• Tube/Collimator Rotation - +/- 110 degrees
• Focal Spot Distance to Floor – 320mm (12.6”) minimum
1990mm (78.4”) maximum
• Maximum SSID to Table Bucky – 1300mm (51.2”)
• Table Base – 1300mm (51.2”) Long
750mm (29.5”) Wide
• Table, Elevating Table Height– Total Movement 350mm ( 13.7”) Min 550mm(21.6”)
Max 900mm (35.4”)
• Table Top – Width – 798mm (31.4”)
Length – 2200mm (86.6”)
• Top Transverse Travel - +/- 120mm (4.7”)
• Top Longitudinal Travel – 600mm (23.6”) to left
500mm (19.7”) to right


Wall Stand


• Center of Detector Height from Floor – 380mm (15”) to 1900mm (74.8”)
• Detector rotation (VK version) - +90 degrees to -20 degrees
• Column Dimensions – 220mm (8.7”) x 186mm (7.3”) x 2230mm (87.8”)
• Optional Kit for Free-Standing (not attached to wall at top of stand)


Generator


• High frequency 50 (65) KW (ma. 450 kHz output)
• kV range – 40 – 150kV
• mA range – 10 – 630mA
mAs range – 0.1 – 630mAs
• Technique Selection – kV/AEC, kV/mAs, kV/mA/ms


DR Detecor


• 14 x 17 HD Csi Wireless
• Image format – 15M Pixels (3556 x 4320)
• Pixel Pitch – 100 micron
• A/D Conversion – 16 bit


X-ray Tube


• Nominal Radiographic tube Voltage – 40 -150kV
• Nominal Focal Spot – Large 1.2mm, Small 0.6mm
• Nominal Anode heat Input Energy – Large 75 kW, Small 27 Kw
• Anode target Angle -12 degrees
• Anode Heat Content -300 kHU


Workstation and Monitor


• 3rd Gen Intel Core
• Windows 7 Professional, 64-bit
• 4GB 2DDR3 SDRAM at 1600 MHz
• 500GB 3.5 SATA 6Gb/s with 16 MB DataBurst Cache
• Monitor – 21.5” (54.6cm) diagonal
• Max Resolution – 1929 x 1080 at 60 Hz
• Aspect ratio – 19.9
• Pixel Pitch – 0.248 x 0.248